Vertical Flow Clean Bench for Laboratory Use

Vertical Flow Clean Bench for Laboratory Use is a high-efficiency clean bench that utilizes vertical laminar flow technology to provide a stable, dust-free workspace that effectively protects experimental samples from contamination. The low noise fan and high efficiency filtration system ensure comfortable operation, and LED lighting enhances visibility. The simple and humanized design is easy to clean and maintain, making it an ideal choice for scientific research, pharmaceutical and electronics industries.
Availability:
Quantity:
  • AM-CB006

  • Amber

  • AM-CB006


The Vertical Flow Clean Bench implements vertical laminar flow technology to deliver a dust-free sterile environment for biological laboratories as well as pharmaceuticals electronics, and food testing facilities etc. A highly efficient filtration system incorporated into the Laminar Flow Clean Bench makes it possible to eliminate air particles and contaminants.


The Laminar Flow Clean Bench eliminates air contaminants by using a high-efficiency filtration system while directing clean air exclusively in one direction for specimen protection, and preventing contamination. The system's small size together with it's stable airflow control mechanism, ergonomic build design enables smooth and effective usage for cleanroom operations in laboratory settings.  


But what safety precautions do I need to take when using the Clean Bench?


To ensure that the Laminar Air Flow Bench is safe to use and to maintain a clean laboratory environment, the following points should be observed during use:  


Avoid blocking airflow


Ensure that the surface of the Clean Bench is kept neat and clean, and do not place excessive items that may affect the stability of the airflow inside the Laminar Flow Hood Bench and reduce cleanliness.  


Use the UV lamp correctly


  • Before use: Turn on the UV lamp for about 15-30 minutes to disinfect.

  • During use: Avoid direct exposure to UV light to prevent damage to skin and eyes.

  • After use: Turn off the UV lamp and start the fan to discharge the residual ozone.


Strictly follow the operating procedures  


When operating inside the Laminar Flow Clean Bench, lab gloves and protective clothing should be worn to avoid contaminating the experimental samples, and operations that may generate aerosols are prohibited inside the bench to avoid affecting the cleanliness.  


Keep away from pollution sources


Try to keep the Clean Bench away from doors, windows, vents and other areas with large air flow to prevent external sources of contamination from entering the work area and affecting the experimental results.  


Daily cleaning and maintenance Clean Bench need to pay attention to what?


To ensure the long-term stable operation of the Laminar Flow Clean Bench, regular cleaning and maintenance is required, including the following:  


Daily Cleaning  


At the end of each day's experiment, a dust-free cloth dipped in sterile alcohol or special cleaner should be used to wipe the surface of the bench to remove any contaminants and dust that may remain. 

 

Regular filter replacement  


High-efficiency filters are key components of the Laminar Air Flow Bench to maintain a clean environment and need to be inspected and replaced regularly according to usage to ensure airflow quality.  


Air Speed Monitoring 


It is necessary to regularly check whether the air speed is within the normal range. If a drop in air speed is detected, it should be checked whether it is caused by clogged filters or malfunctioning fans, and be repaired or replaced in a timely manner. 


Avoid chemical damage


Do not use strong acid, alkali and other corrosive chemicals inside Laminar Flow Hood Bench, so as not to damage the internal structure of the bench and affect its service life.  


During the use of the Vertical Flow Clean Bench, compliance with safety regulations, regular maintenance and correct operation can effectively extend the life of the equipment and improve work efficiency.


Specifications


Model VFCB-1000 VFCB-1500
Outer size mm(W*D*H) 1000*650*1800
1500*650*1800
Work area size mm(W*D*H) 900*600*600 1400*600*600
Cleanliness class 100
Airflow(m³/h) 900 m³/h 1500 m³/h
Air speed(m/s) 0.45±20%
HEPA filter size(mm) 880*570*69*1
760*570*69*2
Filtering efficiency 99.99%@0.3μm
LED light power 20W*1 40W*1
Fan power 190W 270W
Noise <65dB
Voltage AC 220V/50HZ


Clean RoomClean RoomModular Clean RoomClean RoomClean RoomClean RoomClean RoomClean Room



Previous: 
Next: 
Leave a Message
Get A Free Quote

helper

Your phone number or WhatsApp

Your email address

Room 202, No.48, Guancheng area, Guanlong road, Guancheng district,Dongguan city, Guangdong province.

E-mail us

vanessa@amberdg.com

Call us on

+8615015139152
Amber is a professional engaged in providing turnkey solution in a clean room project such as hospital operating room, ICU, ward, pharmaceutical, bio-lab and so on.

QuickLink

Get A Free Quote
Copyright © 2023 Dongguan Amber Purification Engineering Limited All Rights Reserved. Sitemap I Support By Leadong